Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Chinese Journal of Digestion ; (12): 701-707, 2022.
Article in Chinese | WPRIM | ID: wpr-958355

ABSTRACT

Objective:To analyze and evaluate the application of quantitative fecal immunochemical test(FIT) in opportunistic screening of colorectal cancer in asymptomatic population undergoing health checkups.Methods:From January 1, 2018 to December 31, 2021, at the Health Management Center of the First Affiliated Hospital of Soochow University, 53 319 subjects who underwent routine health checkups and with quantitative FIT opportunistic screening for colorectal cancer were selected. Those with positive quantitative FIT results and received colonoscopy were enrolled in the FIT positive group, and those with negative quantitative FIT results and received colonoscopy were enrolled in the FIT negative group. The participation rate and positive rate of quantitative FIT were analyzed. The results of colonoscopy and pathological findings were taken as the gold standard, including normal, non-polyposis lesions, polyposis (hyperplastic and(or) inflammatory polyps, non-advanced adenoma, advanced adenoma), and colorectal cancer, the detection rates of various lesions of the FIT positive and negative groups, the quantitative FIT measurement value of subjects, and the sensitivity and negative predictive value of quantitative FIT for colorectal cancer and advanced adenoma were analyzed. The receiver operating characteristic curve (ROC) was drawn and the area under the curve (AUC) was calculated, the screening efficacy of quantitative FIT for colorectal cancer and advanced adenoma was evaluated. Chi-square test or Fisher exact probability method and Wilcoxon rank sum test were used for statistical analysis.Results:A total of 51 420 cases had completed quantitative FIT, and the total participation rate was 96.44% (51 420/53 319). Quantitative FIT was positive in 2 483 cases (4.83%). The participation rate of colonoscopy in FIT positive group was 26.22% (651/2 483), of which 540 cases were enrolled in FIT positive group. The colonoscopy participation rate of FIT negative group was 1.18% (576/48 937), of which 523 cases were enrolled in the FIT negative group. The detection rates of colorectal cancer and advanced adenoma in FIT positive group were both higher than those of the FIT negative group(3.9%, 21/540 vs. 0, 0/523; 16.1%, 87/540 vs. 3.3%, 17/523), and the differences were statistically significant(Fisher exact probability method and χ2=49.79; both P<0.001). Populations with quantitative FIT values from high to low were those with colorectal cancers, advanced adenomas, non-polyp lesions, non-advanced adenomas, normal, and hyperplastic and (or) inflammatory polyps (1 052.0 ng/mL(390.5 ng/mL, 3 058.0 ng/mL); 294.5 ng/mL (116.8 ng/mL, 951.8 ng/mL); 131.5 ng/mL (10.5 ng/mL, 327.3 ng/mL); 97.0 ng/mL (11.0 ng/mL, 238.0 ng/mL); 20.0 ng/mL (0.0 ng/mL, 175.3 ng/mL); 14.0 ng/mL (0.0 ng/mL, 171.0 ng/mL)), and the difference was statistically significant( H=120.53, P<0.001). The sensitivities(95% confidence interval (95% CI)) of quantitative FIT in colorectal cancer and advanced adenoma were 100.0%(80.8% to 100.0%) and 83.6%(74.8% to 89.9%), respectively. The negative predictive values (95% CI) were 100.0%(99.1% to 100.0%) and 96.7%(94.7% to 98.0%), respectively. The results of ROC analysis showed that the AUCs(95% CI) of quantitative FIT in colorectal cancer and advanced adenoma were 0.874(0.820 to 0.928) and 0.723(0.675 to 0.770), respectively. Conclusions:In this study, the participation rate of quantitative FIT is high. More patients with advanced adenomas and colorectal cancers are found in the high risk popolation with positive quantitative FIT. Quantitative FIT has a good sensitivity and a negative predictive value for colorectal cancer and advanced adenoma. Therefore, positive quantitative FIT-colonoscopies sequential screening should be advocated in population undergoing health checkups for colorectal cancer screening, and it may be applicable to large-scale population screening in China.

2.
Chinese Journal of Digestive Endoscopy ; (12): 309-313, 2017.
Article in Chinese | WPRIM | ID: wpr-619268

ABSTRACT

Objective To investigate the application value of magnetic-controlled capsule endoscopy (MCE) for gastric diseases in physical examination of asymptomatic population.Methods Data of 211 asymptomatic individuals who received MCE examinations from July 2015 to December 2016 in Changhai Hospital were collected and rctrospectively analyzed.The tolerance and safety of MCE were studied by analyzing the detection rate for the focal lesions and the rate of endoscopy transfer.Results Among 211 patients,the detection rate of the gastric focal lesions was 9.5% (20/211).The detection rate in male was higher than that in female (P<0.05).All patients completed MCE examination successfully and no adverse event was reported.Conclusion MCE,a non-invasive endoscopic modality,is safe and better tolerated than conventional endoscopy,and can be used as a promising approach to screening the gastric diseases in asymptomatic population due to high detection rate of these diseases.

3.
Journal of Cardiovascular Ultrasound ; : 244-252, 2015.
Article in English | WPRIM | ID: wpr-58197

ABSTRACT

BACKGROUND: To explore the prognostic performance of coronary computed tomography angiography (CCTA) and exercise electrocardiography (XECG) in asymptomatic subjects. METHODS: We retrospectively enrolled 812 (59 +/- 9 years, 60.8% male) asymptomatic subjects who underwent CCTA and XECG concurrently from 2003 through 2009. Subjects were followed-up for major adverse cardiac events (MACE) including cardiac death, nonfatal myocardial infarction, unstable angina, and revascularization after 90 days from index CCTA. RESULTS: The prevalence of occult coronary artery disease (CAD) detected by CCTA was 17.5% and 120 subjects (14.8%) had positive XECG. During a mean follow-up of 37 +/- 16 months, nine subjects experienced MACE. In multivariable Cox-regression analysis, only the presence of CAD by CCTA independently predicted future MACE (p = 0.002). Moreover, CAD by CCTA improved the predictive value when added to a clinical risk factor model using the likelihood ratio test (p < 0.001). Notably, the prognostic value of CCTA persisted in the moderate-to-high-risk group as classified by the Duke treadmill score (p = 0.040), but not in the low-risk group (p = 0.991). CONCLUSION: CCTA provides incremental prognostic benefit over and above XECG in an asymptomatic population, especially for those in a moderate-to-high-risk group as classified by the Duke treadmill score. Risk stratification using XECG may prove valuable for identifying asymptomatic subjects who can benefit from CCTA.


Subject(s)
Angina, Unstable , Angiography , Coronary Artery Disease , Death , Electrocardiography , Follow-Up Studies , Myocardial Infarction , Prevalence , Retrospective Studies , Risk Factors
4.
Journal of Cardiovascular Ultrasound ; : 54-59, 2009.
Article in Korean | WPRIM | ID: wpr-221813

ABSTRACT

BACKGROUND: Left ventricular (LV) remodeling manifests as an increase in LV end-diastolic and end-systolic volumes, an increase in myocardial mass, and a change in chamber geometry to a more spherical shape, and has been considered to be a consequence of heart failure, myocardial infarction or mitral regurgitation. However, less is known about change of LV geometry, especially LV sphericity, in asymptomatic population according to aging. METHODS:We investigated 261 asymptomatic subjects who volunteered for health screening and underwent transthoracic echocardiography. Those with poor echo image, significant coronary artery disease, LV dysfunction, hypertension, and diabetes mellitus were excluded. LV sphericity index is defined as the ratio of the long-axis length divided by LV short-axis length, both during systole and diastole. LV mass was calculated from septal and posterior wall thickness and LV internal dimension at end-diastole and then divided by body surface area to calculate LV mass index RESULTS: The mean age of subjects was 49.6+/-6.7 years and the percentage of male was 81%. LV sphericity index at diastole showed significant correlation with age (r=-0.17, p value<0.01), but LV sphericity index at systole did not. Both indices did not showed significant association with aerobic fitness, blood pressure, glucose, insulin resistance and LV function. LV mass index showed significant correlation with age (r=0.14, p value<0.05). CONCLUSION: Among the parameters of LV geometry, sphericity index showed decrease with aging in healthy population, meaning LV becoming more spherical with aging. Longitudinal follow-up study is needed to determine its usefulness as a predictor of future LV dysfunction in asymptomatic population.


Subject(s)
Humans , Male , Aging , Blood Pressure , Body Surface Area , Coronary Artery Disease , Diabetes Mellitus , Diastole , Echocardiography , Glucose , Heart Failure , Hypertension , Insulin Resistance , Mass Screening , Mitral Valve Insufficiency , Myocardial Infarction , Systole
SELECTION OF CITATIONS
SEARCH DETAIL